Industrial
Hygienic
Instrumentation

 


I TYPE SINGLE SEAT VALVE


IMPLEMENTATION
I-SSV is a single seal valve offering a wide range of implementation areas as a dual or triple way stop valve or three or five way flow diversion valve, with a flexible design that operates with air.

OPERATION PRINCIPLE
The valve is controlled remotely with pressurized air. Few number of simple moving parts in its content make it a reliable and long-lasting valve.

STANDARD DESIGN
I-SSV consists of an actuator, gaskets, cover and valve bodies. All components are combined with clamp rings and a shaft terminal fitting.  The valve is only partially combined when shipping to simplify its installation.  The valve is welded as a standard.

ACTUATOR FUNCTION
(NC) opened by pulling up the piston as a standard, optionally normally open (NO) and Air/Air (A/A), dimensions 25-101,6 mm
/ DN25-100. Actuator for the intermediary position of valve cover as an option, dimensions 25-101,6 mm / DN25-100.

Note:
I-SSV valve is designed, tested and approved according to EHEDG standard.


TECHNICAL DATA
Maximum product pressure .......................... 1000 kPa (10 bar)
Minimum product pressure............................ Full vacuum
Temperature Range, standard  Gasket.......... (-)10°C to + 100°C (EPDM)
Air pressure, actuator..................................... 500-700 kPa (5-7 bar)

MATERIALS
Parts that come into
contact with the product....................................Stainless steel 1.4307 (304L)
Surface............................................................. Semi-lustrous.
Other Stainless Parts....................................... 1.4307 (304L)
Cover shaft ..................................................... 1.4307 (304L)
Gaskets that come into
contact with the product.................................... EPDM (standard)
Other Gaskets................................................... Nitrile (NBR)


















a) Shut-Off Valve


b) Change Over Valve

























































Factors Affecting Opening/Closing Time:
• Air supply (air pressure)
• Length and dimensions of air hoses
• Number of valves connected to the same air line
• Use of single Solenoid valve for serially-connected air
  actuator functions
 • Product Pressure.

Air Connections Pressurized air:
1/8” (BSP), Annular gear.